HUS transformer based, online is UPS is a hi-tech product which combines digitalization, information and modularization into one, has powerful information collection, signal processing, detection and complete protection system.
It can combine multiple power sources (such as solar panels, utility power or a generator) to deliver non-intermittent, reliable and high-quality AC power to government, pastorals, hospitals, banks, airports, pastoral areas, boarders, islands, communication base station, industries, etc.
The modular design with flexible configuration brings customers the optimized social, economical and environmental benefits.
MODEL | HUS 50kW | HUS 65kW | HUS 80kW | HUS 100kW | HUS 160kW | HUS 250kW | HUS 320kW | |
---|---|---|---|---|---|---|---|---|
Rated capacity | 50kW | 65kW | 80kW | 100kW | 160kW | 250kW | 320kW | |
AC input | Input voltage range | 380/400/415 Vac ±20%, 3 phase and 4 wire | ||||||
Input frequency | 50/60 Hz ±10% | |||||||
AC output | Voltage | 380/400/415 Vac ±1% (static state) | ||||||
Max output voltage | 432Vdc | |||||||
Frequency | 50/60Hz ±0.5% | |||||||
Crest factor | 3:1 | |||||||
Efficiency | >99% in city power mode; >80% in inverter mode | |||||||
Waveform | Pure sine wave | |||||||
Power factor | 0.8-1 lagging | |||||||
THD | <3% on linear load, <5% on nonlinear load | |||||||
Overload capability | 130% for 10 minutes; 130%-150% for 1 minute | |||||||
Working mode | City grid prior | UPS working mode, with city grid as power supply, battery as backup | ||||||
Eco mode | Suitable for special occasion | |||||||
PV prior | Battery as main power supply | |||||||
Battery | Type | Maintenance free lead-acid cell | ||||||
DC voltage | 384Vdc (12Vdc x 32pc) | |||||||
Charge current | 6-30A | |||||||
Bypass | Phase | 3-phase + N | ||||||
Rated frequency | 50Hz-60Hz ±5% | |||||||
Inverter/Bypass transfer time | 0ms (overload) | |||||||
System | Efficiency | >96% | >94% | |||||
Rated frequency | 50Hz-60Hz ±5% | |||||||
Inverter/Bypass transfer time | 0ms (over-load) | |||||||
LCD display contents | Operating status, menu operation, voltage, current, parameter, model | |||||||
LED display contents | Inverter operation, rectification error, operation error | |||||||
Communication interface | RS232 / RS485 | |||||||
Electrical protections | Input & output over/under voltage, overload, short circuit, over temperature, reverse polarity, lighting surge protection | |||||||
Environmental | Noise | ≤65dB | ≤68dB | |||||
Temperature | 0°C to 40°C | |||||||
Humidity | 30%-90% (non-condensing) | |||||||
Dimensions (mm) | 1000x900x1680 | 1600x980x1800 | ||||||
Gross Weight (kg) | 840 | 940 | 1010 | 1700 | 2200 | 2300 | 2600 |