MPPT Solar CHarge Controllers are designed for solar off-grid photovoltaic power generation. They are specially used in industrial and mining charging and discharging management systems.
Model (MP) | 30A | 40A | 50A | 60A | 80A | 100A | |
---|---|---|---|---|---|---|---|
Voltage | 12~48V | ||||||
Charging patterns | MPPT automatic maximum power point tracking | ||||||
Charging modes | Constant current (MPPT), balanced charge, floating charge | ||||||
Voltage range | 12V system | 9~15Vdc | |||||
24V system | 18~30Vdc | ||||||
36V system | 27~45Vdc | ||||||
48V system | 36~60Vdc | ||||||
Maximum solar panel power input | 12V system | 420W | 570W | 700W | 900W | 1120W | 1400W |
24V system | 840W | 1130W | 1400W | 1700W | 2250W | 2800W | |
36V system | 1230W | 1700W | 2100W | 2550W | 3350W | 4200W | |
48V system | 1650W | 2250W | 2800W | 3400W | 4400W | 5500W | |
Model (MP) | 30A | 40A | 50A | 60A | 80A | 100A | |
Voltage | 60~96V | 96~192V | |||||
Charging patterns | MPPT automatic maximum power point tracking | ||||||
Charging modes | Constant current (MPPT), balanced charge, floating charge | ||||||
Voltage range | 60V system | Manual settings | |||||
72V system | Manual settings | ||||||
96V system | 72~120Vdc | ||||||
192V system | 144~240Vdc | ||||||
Maximum solar panel power input | 60V system | 2000W | 2800W | 3500W | 4200W | 5300W | 6800W |
72V system | N/A | 3360W | 4200W | 5000W | 6400W | 7950W | |
96V system | N/A | N/A | 5500W | 6500W | 8500W | 10600W | |
192V system | N/A | N/A | N/A | N/A | 16000W | 20000W | |
MPPT working voltage range | 12V system | 18~150Vdc | |||||
24V system | 34~150Vdc | ||||||
36V system | 48~150Vdc | ||||||
48V system | 65~150Vdc | ||||||
60V system | 72~150Vdc | ||||||
72V system | 80~150Vdc | ||||||
96V system | 130~180Vdc | ||||||
192V system | 260~420Vdc | ||||||
Limiting input voltage | 12/14/36/48/60/72V (160V) | 96V (235V) | 192V (430V) | ||||
Protection | Overvoltage, undervoltage, polarity reverse connection, short circuit, overtemperature | ||||||
Communication | RS485, Wifi / GPRS (optional) | ||||||
Soft start time | ≤10s | ||||||
Dynamic response recovery time | ≤500µs | ||||||
Machine efficiency | ≥96.5% | ||||||
PV module utilization | ≤99.97% | ||||||
Battery type (optional) | Lead-acid maintenance-free battery, gel battery, liquid battery, Li-battery | ||||||
PV configuration (recommended) | 12V system | 18~60V [30V module (x1), 36V module (x1)] | |||||
24V system | 36~72V [30V module (x2), 36V module (x2)] | ||||||
36V system | 60-144V [30V module (x4), 36V module (x3), 40V module (x2)] | ||||||
48V system | 72~144V [30V module (x4), 36V module (x3), 40V module (x2)] | ||||||
60V system | 72~144V [30V module (x4), 36V module (x3), 40V module (x2)] | ||||||
72V system | 108~144 [30V module (x4), 36V module (x4), 40V module (x3)] | ||||||
96V system | 144~180V [30V module (x6), 36V module (x5), 40V module (x4)] | ||||||
192V system | 240~400V [30V module (x10), 36V module (x9), 40V module (x9)] | ||||||
ENVIRONMENTAL | |||||||
Altitude | 0~3000m | ||||||
Humidity | 10~90% (non-condensing) | ||||||
Temperature | -20~40°C | ||||||
Mechanical protection type | IP21 |